ATEX Certified Digital Refrigerant Recovery Machine

Fieldpiece Instruments B.V. Stand: 5B28a
ATEX Certified Digital Refrigerant Recovery Machine
ATEX Certified Digital Refrigerant Recovery Machine
ATEX Certified Digital Refrigerant Recovery Machine
  • For Use With: A3, A2L, and A1 Refrigerants
  • Not for Use With: E170, R429A, R432A, R435A, R510A, R-610, R-702, R-717, R-744 or R-1150
  • Display: Backlit LCD with status messages
  • Auto-Stop Levels: 0 bar (default) (0 psig or 0 kPa); -0.34 bar (-10 inHg or -25 cmHg); -0.68 bar (-20 inHg or -50cmHg)
  • WARNING: EXPLOSION HAZARD. When recovering A3 refrigerants, DO NOT use an Auto-Stop setting other that 0 psi (default), in order to avoid mixing air with recovered refrigerant.
  • Input Port High Pressure Cutoff: 26.0 bar (2600 kPa, 377 psig)
  • Output Port High Pressure Cutoff: 38.5 bar (3850 kPa, 558 psig)
  • Input and Output Port Pressure Sensor Range: -1 bar to 50 bar (-30 inHg to 725 psig, -76 cmHg to 5000 kPa)
  • Pressure Sensor Accuracy: ± 0.15 bar (± 2.176 psig) above atmospheric pressure, ± 0.2 bar (± 6 inHg) vacuum
  • Final Recovery Vacuum: -0.51 bar (-38 cmHg, -14.9 inHg)
  • Compressor: Twin cylinder reciprocating (oil-less)
  • DC Motor: 1 HP (variable smart speed)
  • RPM: 3000
  • Nominal Power: 110V~50Hz (MR53UK); 220-240V~50/60Hz (MR53INT)
  • Nominal Current Draw: 14A @ 110V (MR53UK); 7A @ 230V (MR53INT)
  • Valve: Single dual-route ball valve
  • Input Port Filtration: 9 mm mesh screen, stainless
  • Dimensions: 376 mm x 250 mm x 344 mm (14.8” x 9.8” x 13.5”)
  • Weight: 11 kg (24 lbs)
  • Operating Environment: 0°C to 40°C 
  • Storage Environment: -20°C to 60°C 
Loading